    In HVT (High profile Technology), any voltage above 11 kilo-volts is recognized as from the high profile range. It might be either alternating or dc. Most of industries are supplied with this particular variety of voltages in the national grid even though some generates their particular high profile power using generators. Higher than normal voltages usually are stepped into some specific lower voltages, to run their electrical machinery like motors, heaters, HVAC systems, and others. Of those industries, regular checks has to be conducted by authorized personnel to assess the healthiness of their equipment. Equipment tests are very essential in determining the steadiness of a machine to be able to avoid equipment breakdown and big production losses. These tests also assist in determining in case a newly purchased products are worth, before setting it up. Most manufacturers use hollywood testing to check the insulation of the equipment before supplying them to their customers.

    The main advantages of applying high voltage insulation testing are usually looked down upon by a lot of industries, being a technique of determining the conditionality of these electrical equipment. This can be greatly caused by the truth that much pressure and emphasis is obviously place on production activities on the worth of proactive upkeep of the equipment. A reliable and efficient insulation on an electrical machine is most important due to the correct operation every time. Since insulation of equipment degrades as time passes, the respective electrical department for any industry has to be regularly conducting regular check-ups for machines within their normal working schedule. Do that to even low and medium voltage systems.

    In many instances, a four stage process is followed. The stages are briefly described below:

    In-process testing

    This is the simplest process that may be done even about the readily installed equipment, as long as it is not running. This procedure demands the use of a meggering instrument to check the insulation integrity from the coils before it’s attached to phases, neutral, and earth. In some cases, a multimeter may also be used. Inter-winding and winding-to-body resistances are checked at this stage. Therefore, the dielectric withstanding voltage and insulation resistance with the coil can be discovered.

    Ancillary Equipment Testing

    This requires testing for insulation resistance and dielectric withstanding voltage for interconnecting cables, hollywood bushings, busbars, and terminations. This is conducted in the event the components are interconnected or separated.

    Generator Assembly Test

    In this case the generator is visually inspected. Cleaning is performed as well as the machine’s stability can also be assessed. The heartbeat from the machine is assessed using a special display instrument. The apparatus is also meggered for insulation resistance and dielectric withstanding voltage test.

    On the list of a few in testing equipment are; voltage and right testing equipment. For dependable results testing voltage needs to be adequate to effectively look at the insulating resistance. However, it should not be too much to overstress the device insulation. The right testing equipment that may effectively store results allows them to be stored in a pc for archiving and analysis. This process saves time and cuts down on the risk of error.